Navigating the SFDA medical device registration in Saudi Arabia, particularly the Medical Device Marketing Authorisation (MDMA) process, is essential for manufacturers seeking entry into the rapidly expanding Saudi market.

The MDMA requirements have evolved to cope with the advancement of international standards, such as the evolution from EU Medical Device Directives (MDD) to Medical Device Regulations (MDR). The continuous development of medical device regulations in Saudi Arabia has increased the complexity of this process.

For example, even low-risk medical devices (supplies and consumables) became in need of an authorised representative (AR) and an MDMA approval.

We at PharmaKnowl offer expert support for the registration process. Whether you’re dealing with new devices or modifying existing products, our team provides the strategic insight and technical expertise needed to achieve timely and successful market entry in Saudi Arabia.

This article clarifies the SFDA medical device registration requirements and defines the classification differences.

Pour les autres types d’enregistrement de produits, reportez-vous à la publication d’enregistrement SFDA .

Registration Application Types

La SFDA réglemente les dispositifs médicaux en Arabie saoudite afin de garantir leur sécurité, leur efficacité et leur qualité. Les fabricants doivent obtenir l’approbation de la MDMA avant de commercialiser leurs produits. Après l’approbation, ils sont responsables des rapports de sécurité et d’autres opérations de gestion du cycle de vie, telles que la mise à jour, le renouvellement et la soumission de l’identification unique du dispositif (UDI) .

Voici un résumé des procédures d’enregistrement des dispositifs médicaux :

MDNR (faible risque) – Annulé

Companies used to register Non-sterile, non-measuring, Low-Risk Medical Devices through the Medical Device National Registry (MDNR), also known as « Medical Devices Listing, » which is exempt from MDMA and AR. However, in September 2022, the SFDA cancelled the MDNR procedure. Therefore, all devices must have a technical file for MDMA with an appointed AR in Saudi Arabia.

MDMA 1 (GHTF) – Annulé

Dans le cadre de cette procédure de candidature, la SFDA a examiné les approbations des pays membres du GHTF, tels que l’Union européenne, les États-Unis, le Canada, l’Australie et le Japon. Cette procédure était simple à suivre, sans investigations techniques approfondies. Cependant, fin 2021, la SFDA a annulé cette procédure.

If your product was registered initially through MDMA 1, you can still use the same route to file renewals, minor updates, or variations. But the SFDA will still request the full technical file during the process.

MDMA 2 (TFA)

From January 2022, all medical devices and in vitro diagnostics (IVDs) must receive an SFDA authorisation through the Technical File Application (TFA) registration route (MDMA2). This route resulted from the authority’s continuous regulation updates influenced by the EU MDR and IVDR. It requires presenting the technical documentation in a clear, searchable, and organised manner.

Par conséquent, les exigences d’enregistrement sont devenues plus strictes. De nombreuses conditions doivent être remplies et des études doivent être fournies, telles que des rapports d’évaluation clinique (REC), des rapports de tests de biocompatibilité et la nécessité de réaliser une étude de suivi clinique post-commercialisation (PMCF) en Arabie saoudite.

Bien que les exigences de la TFA soient similaires à celles de l’UE (marquage CE), la SFDA n’exige pas de certificat CE. Cependant, si le dossier du produit ne porte pas de marquage CE, il sera soumis à une évaluation rigoureuse.

Conditions d’inscription

Voici un résumé des exigences, qui varient selon le type et la classe de produit. Voici les sections principales du dossier d’enregistrement :

  • Administrative & Product Identification
    • Table of contents
    • Description de l’appareil
    • Utilisation/but prévu
    • Device Classification
    • Model, Sizes, Accessories, and Variants
    • Device label and Packaging Information
    • Instructions for use (IFU)
    • Informations sur la conception
    • Informations sur la fabrication
    • Device History (Approvals from Reference Countries)
  • Safety, Risk & Performance Documentation
    • Essential Principles (EP List) of Safety & Performance (Required checklist)
    • Analyse des bénéfices et des risques
    • Dossier de gestion des risques (plan et rapport)
    • Preclinical testing data
    • Biocompatibility Test Reports.
    • Electrical Safety, EMC, Software validation (as applicable)
    • Sterilisation and Shelf-Life Validation (if sterile)
  • Clinical Evaluation & Surveillance

Download: Checklist of SFDA Medical Device Required Files for MDMA application

Processus d'enregistrement et d'approbation de la MDMA SFDA Arabie saoudite

Processus d’inscription

Time needed: 90 days

Nous pouvons résumer le processus d’approbation de l’enregistrement des dispositifs médicaux (MDMA) dans les quelques étapes suivantes :

  1. Désignation d’un représentant autorisé (AR)

    Manufacturers must appoint an AR to represent their company in Saudi Arabia. An AR license will be issued by SFDA, after which the AR can apply for the device registration.

  2. Analyse des écarts

    Applicant must establish a thorough gap analysis of the registration file vs. all applicable requirements. Identifying the gaps is essential to determining the relevant studies and tests, such as Stability, CER, Biocompatibility, risk management, and PMCF.

  3. Soumission de MDMA

    Le demandeur soumet le dossier technique à la SFDA .

  4. Validation

    SFDA garantit de bonnes pratiques de soumission sans évaluer son contenu.

  5. Paiement des frais

    The applicant will receive an SFDA invoice to pay before the start of the assessment.

  6. Évaluation de la candidature

    The SFDA evaluators will review the file and send back their inquiries in multiple waves.

  7. Approbation de la MDMA

    The legal manufacturers receive an MDMA certificate that permits them to market the product in Saudi Arabia.

Classification

Applicants must classify their products according to the SFDA medical device classification rules within the MDMA application. These rules correspond to the EU regulation (CE certificate) since they are the unofficial SFDA reference regulations, but do not necessarily match them.

Dispositif médical

SFDA medical device classification is either Class A, B, C, or D, based on the risk class. The class is necessary to determine the registration procedure and its requirements, as discussed in the table below:

Classification SFDAClasse de risqueRègle de classification MDR
Classe AFaibleje
Classe A – StérileFaible-moyenEst
Classe A – Fonction de mesureFaible-moyenJe suis
Classe A – Instruments chirurgicaux réutilisablesFaible-moyenJe
Classe BFaible-moyenIIa
Classe CMoyen-élevéIIb
Classe DHautIII
Medical Device Classification in the Saudi Food and Drug Authority (SFDA)

La classification est la suivante :

  • Utilisation prévue.
  • Niveau de risque (probabilité et gravité des dommages pour les patients, les utilisateurs et les autres).
  • Nature of the device on or within the human body (e.g. invasive)
  • Use duration (transient, short-term, long-term)

Identical devices could be classified differently according to the targeted body part or clinical setting. Therefore, the intended use is crucial in determining the correct classification. The intended use reference is reflected in the following:

  • Mode d’emploi (IFU)
  • Étiquette
  • Matériel promotionnel
  • Fiche technique

In Vitro Diagnostics (IVDs)

For in vitro diagnostic medical devices, the (SFDA) uses a risk-based classification system broadly aligned with the International Medical Device Regulators Forum (IMDRF) principles and is similar in structure to the EU IVDR, though applied independently.

Classification SFDA IVDClasse de risqueRègle de classification
Classe AFaible risque individuel et faible risque pour la santé publiqueUN
Classe BRisque individuel modéré et/ou risque faible pour la santé publiqueB
Classe CRisque individuel élevé et/ou risque modéré pour la santé publiqueC
Classe DRisque individuel élevé et risque élevé pour la santé publiqueD
IVD Classification in the Saudi Food and Drug Authority (SFDA)

Le demandeur est responsable de déterminer la classe du DIV en :

  • Appliquer les règles de classification des dispositifs médicaux DIV, et
  • Considérant :
    • Utilisation prévue
    • Niveau de risque

Bundling Multiple Devices

Grouping multiple devices in the same application is permissible; the applicant may bundle up to 50 items in one MDMA application. However, products must meet several conditions, such as having the same legal manufacturer, the same risk class, and the same intended use.

Bundling TypeCriteriaExamples
Single ProductA device sold in multiple sizes or models with the same intended useSyringes with different volumes
FamilyDevices with the same risk class, manufacturer, design, and intended useCatheters of varying lengths
SystemDevices intended to operate together for a common purposeECG machine + electrodes + leads
SetDevices packaged together and intended for a common medical purposeSurgical kits or dental kits
Software SuiteRelated software modules that work as part of the same platformHospital management or imaging analysis software
IVD’sCan be bundled in case of the same risk class, manufacturer, design, and intended useBlood collection tubes, Culture media

Chronologie

The assessment timelines vary according to many factors, such as risk class, complexity of the product, number of bundled products, and the completeness of the file. Unidentified gaps before the submission may delay the approval. The entire timeline for the registration project includes:

  • Gap Analysis Time
    This part depends on the number and type of gaps, the speed of manufacturer feedback, and the regulatory staff’s experience.
  • Temps d’évaluation SFDA
    Pour connaître les délais d’examen officiels, reportez-vous à notre article Délais SFDA .

Frais

Les frais de demande d’homologation de MDMA varient selon la classe de risque du dispositif médical et le nombre de produits concernés. Pour plus d’informations, consultez notre article actualisé sur les frais SFDA .

Renouvellement

La validité par défaut de la MDMA est de trois ans. Lorsque l’autorisation de mise sur le marché approche de son expiration, les fabricants peuvent soumettre une demande de renouvellement jusqu’à trois mois (90 jours) avant la date d’expiration. Si l’autorisation de mise sur le marché est obsolète (GHTF), le processus de renouvellement sera long et exigeant, tout comme pour un nouvel enregistrement. En revanche, le renouvellement de la MDMA2 sera plus rapide.

Mise à jour

Pour apporter des modifications au dispositif médical enregistré, les fabricants doivent soumettre une demande de mise à jour MDMA .

Certificat MDMA

SFDA délivrera un certificat MDMA en arabe et en anglais contenant les éléments suivants :

  • Les informations du fabricant (titulaire de la licence)
  • Nom du dispositif médical et informations sur le groupe de dispositifs médicaux.
  • Période de validité
  • Numéro de certificat
En-tête d'un certificat MDMA

Catégories de produits

Voici des exemples de types et de catégories de dispositifs médicaux en Arabie saoudite :

  • Appareils de diagnostic :
    • Matériel d’imagerie : appareils à rayons X, scanners CT.
    • Appareils de surveillance : appareils ECG et tensiomètres.
    • Dispositifs de diagnostic in vitro : tests de grossesse, lecteurs de glycémie.
  • Dispositifs thérapeutiques :
    • Appareils respiratoires : ventilateurs, nébuliseurs.
    • Dispositifs de perfusion : pompes à insuline et équipement de thérapie intraveineuse.
    • Appareils de rééducation : Fauteuils roulants, prothèses.
  • Dispositifs implantables :
    • Dispositifs cardiovasculaires : stimulateurs cardiaques, stents.
    • Implants orthopédiques : prothèses de hanche, tiges vertébrales, prothèses articulaires.
  • Instruments chirurgicaux :
    • Instruments coupants : Scalpels, ciseaux chirurgicaux, pinces.
    • Agrafeuses et sutures : Agrafeuses chirurgicales, sutures résorbables.
  • Appareils dentaires :
    • Matériaux de restauration : Couronnes dentaires, obturations.
    • Appareils orthodontiques : appareils orthodontiques, appareils de contention.
    • Autre : fraises dentaires
  • Appareils ophtalmiques :
    • Lentilles correctrices : Lentilles de contact, lunettes.
    • Matériel chirurgical : machines LASIK, lentilles intraoculaires.
  • Logiciel médical (SaMD) :
    • Logiciel de diagnostic : IA pour l’analyse d’images.
    • Logiciel de planification de traitement : outils de planification de radiothérapie.
  • Equipement de laboratoire:
    • Analysers: Blood gas analysers and haematology analysers.
    • Sterilisation equipment: Autoclaves, UV sterilisers.
  • gaz médicaux
  • Appareils de soins à domicile :
    • Appareils de surveillance : glucomètres et thermomètres numériques.
    • Aides à la mobilité : déambulateurs, scooters électriques.
  • Dispositifs thérapeutiques (par exemple, machines de dialyse)

Licence d’importation de dispositifs médicaux (MDIL)

Importing medical devices requires a valid MDMA. However, the SFDA may exempt some medical devices from registration and only require them to issue a medical device importing license (MDIL). For example:

  • Demonstration or training purposes, medical devices.
  • Produits chimiques (produits finis), qu’ils soient classés comme dispositifs médicaux ou utilisés avec des dispositifs médicaux (par exemple, les gaz utilisés pour calibrer les dispositifs médicaux, ainsi que les produits chimiques utilisés pour assurer la stérilisation des dispositifs médicaux, la fabrication de prothèses et la préservation des tissus ou des cellules). Sont exclus les produits suivants (si le produit chimique est classé comme dispositif médical et que le dispositif doit contenir de la MDMA).
    • Matériaux radioactifs
    • Diagnostic in vitro médical
    • DIV non médical
    • Précurseurs chimiques.
  • Les appareils de distillation destinés aux prestataires de soins de santé ou aux établissements d’enseignement.
  • Produits à usage recherche et éducation.
  • Dispositifs/fournitures médicales semi-finis (et produits chimiques bruts et non bruts) destinés à la fabrication locale (la fabrication comprend la remise à neuf, l’assemblage, l’emballage et l’étiquetage).

Enregistrement de la société

The SFDA also regulates medical device companies, enforcing different requirements for local and international companies to receive an SFDA license to manufacture, import, or distribute medical devices. Below are the requirements for both types:

Entreprise locale saoudienne

The SFDA licenses local medical device companies such as importers, distributors, warehouses, authorized representatives, and manufacturers. The local company license name is the Medical Device Establishment License (MDEL). All previous types of companies must implement a quality management system (QMS) and have an ISO 13485 certificate.

International legal manufacturers must appoint an authorised representative (AR) in Saudi Arabia; this is the first step in enabling communication with the SFDA. The AR’s primary responsibility is product compliance in pre- and post-marketing activities. The AR will maintain registration status, facilitate shipments, monitor safety, report cases, and represent the company in regulatory or legal matters.

Service d’inscription

Whether your company is new to or already active in the Saudi market, PharmaKnowl will help you comply with the SFDA and facilitate your business by providing compliance, insights, and supply management to your distributors without shipment commission.

PharmaKnowl is an SFDA-licensed service provider in Saudi Arabia representing well-known international companies. Contact us to schedule an exploratory meeting or request more information.

Frequently Asked Questions

What is Medical Device Marketing Authorisation (MDMA) in Saudi Arabia? 

MDMA is the official approval issued by the Saudi Food and Drug Authority (SFDA) that allows a medical device or IVD to be marketed in the Kingdom. It confirms that the product meets all local regulatory, safety, and performance requirements based on a technical file review. 

How long is the SFDA MDMA certificate valid?

The MDMA certificate is valid for three years. Renewal can be initiated up to 90 days before expiration.

Is an Authorised Representative (AR) mandatory for SFDA MDMA approval?

Yes. For international manufacturers, appointing an SFDA-licensed Authorised Representative (AR) is mandatory to submit the MDMA application and manage post-market obligations in Saudi Arabia. 

What are the timelines for MDMA registration in Saudi Arabia? 

The typical MDMA timeline is 35 business days if all requirements are fulfilled, but the timeline can vary due to technical file gaps, product complexity, or missing documentation.

Can multiple medical devices be registered under one MDMA application?

Yes. A maximum number of 50 medical devices can be grouped/bundled into a single MDMA application as long as they meet bundling criteria. 

What happens if I miss the MDMA renewal deadline?

The company is not allowed to market its product when the certificate expires. The company must renew as soon as possible and ensure its AR license is valid.

Does SFDA accept CE mark or US FDA approval?

While prior approval (e.g., CE mark, FDA 510(k)) can support your application, the SFDA conducts an independent evaluation. MDMA approval is not granted automatically based on foreign registrations. SFDA does not require CE or FDA approval as long as the full technical file is available according to SFDA requirements.  

What’s the difference between MDMA and MDEL?

MDMA applies to the product registration certificate for a medical device or IVD in KSA, while MDEL is the importer or distributor license.

What’s the difference between MDMA-1 and MDMA-2?

MDMA-1: Registration route based on approvals from Global Harmonisation Task Force (GHTF) countries: EU, US, Canada, Australia, Japan. It was easier and faster without the need for complete technical files. However, this route was cancelled by SFDA and replaced with MDMA 2.
MDMA 2, which is the current registration route (since 2022). It requires complete Saudi-specific technical files (similar to EU MDR standards) and undergoes a more stringent SFDA evaluation. It does not require any prior GHTF approvals.

À propos de l’auteur

Mohammed Jobran

Consultant en réglementation (pharmacien BSc, informatique biomédicale MSc). Avec 19 ans d'expérience au sein de la SFDA, de sociétés multinationales et en tant que consultant professionnel.

Services

Événements

Des questions ? Restons connectés.

Contactez-nous pour planifier un appel, demander des détails ou obtenir une proposition sur mesure.